Screw air compressors have a long service life, generally over 10 years. However, this doesn't mean that once purchased and put into production, they can be used indefinitely, just like other mechanical equipment. Regular maintenance is necessary to ensure the compressor remains in good working order and extends its lifespan.
I. The service life of compressor lubricating oil is generally around 2000 hours. It must be replaced after this time. When replacing, not only should the lubricating oil in the oil tank be completely drained, but also the residual oil in the oil shut-off valve, oil cooler, and oil pipelines must be completely removed to ensure the cleanliness of the newly added oil. Pay attention to the quality of the lubricating oil when selecting it, and monitor the oil level during operation. The oil level indicator must be within the correct range—neither too high nor too low. Lubricating oil temperature should also be carefully controlled to prevent water contamination.
II. Regularly check for leaks. In most systems, air leaks of 10%-25% are typical. If compressed air leaks, the unit must continuously load to maintain pressure, consuming more energy and leading to faster lubricant loss, requiring earlier lubricant replenishment.
III. Regularly lubricate the motor and periodically measure current and voltage. A 1% imbalance in three-phase voltage can cause a current exceeding 10% in one phase; a 3.5% imbalance can increase motor temperature by 25℃. Therefore, regularly check current and voltage to reduce production costs and improve machine efficiency. Also, ensure the motor is wired correctly to prevent reverse rotation, which can damage or seize the bearings.
IV. Regularly replace the three filters. Screw air compressor filters have a service life (generally 2000 hours) and must be replaced promptly when due. Failure to do so may cause filter clogging or even rupture, leading to increased temperature, reduced performance, and other malfunctions, resulting in greater losses.
V. Check for abnormal loading/unloading, starting/stopping, and exhaust pressure; monitor excessive vibration or unusual noise during operation; and check for malfunctions in the minimum pressure valve, temperature control valve, and oil shut-off valve.